Dell S6000 FTOS 9.0(2.0) Command Line Reference Guide for the System - Page 453
Description, Diagnostic Data in show interfaces transceiver, continued
View all Dell S6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 453 highlights
Table 20-9. Diagnostic Data in show interfaces transceiver (continued) Line Description Bias Low Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. TX Power Low Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. RX Power Low Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. Temp High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Voltage High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Bias High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. TX Power High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. RX Power High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Temp Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Voltage Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Bias Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. TX Power Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Power Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Temperature Current temperature of the sfps.If this temperature crosses Temp High alarm/ warning thresholds, then the temperature high alarm/warning flag is set to true. Voltage Current voltage of the sfps.If this voltage crosses voltage high alarm/warning thresholds, then the voltage high alarm/warning flag is set to true. Tx Bias Current Present Tx bias current of the SFP. If this crosses bias high alarm/warning thresholds, then the tx bias high alarm/warning flag is set to true. If it falls below the low alarm/warning thresholds, then the tx bias low alarm/warning flag is set to true. Tx Power Present Tx power of the SFP. If this crosses Tx power alarm/warning thresholds, then the Tx power high alarm/warning flag is set to true. If it falls below the low alarm/warning thresholds, then the Tx power low alarm/ warning flag is set to true. Rx Power Present Rx power of the SFP. This value is either average Rx power or OMA.This depends upon on the Rx Power measurement type displayed above. If this crosses Rx power alarm/warning thresholds, then the Rx power high alarm/warning flag is set to true. If it falls below the low alarm/warning thresholds, then the Rx power low alarm/warning flag is set to true. Data Ready state Bar This field indicates that the transceiver has achieved power up and data is ready. This is set to true if data is ready to be sent, false if data is being transmitted. Rx LOS state This is the digital state of the Rx_LOS output pin.This is set to true if the operating status is down. Tx Fault state This is the digital state of the Tx Fault output pin. Rate Select state This is the digital state of the SFP rate_select input pin. Interfaces | 453