Sony XVS-7000 Users Guide - Page 415
Copying Cross-Point Assign Tables, Copying Cross-Point Settings
View all Sony XVS-7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 415 highlights
To set sequential names for multiple signals When multiple signals are selected and you specify a number suffix for a signal name, all of the selected signals are automatically assigned names ending with sequential numbers. Example: To assign sequential names to the three source signals 2 to 4 (1) Set the [Source No] parameter to 2 and the [Num] parameter to 3 in step 2. (2) Set the name of source signal 2 to "CAM2." The name "CAM3" is assigned automatically to source signal 3, and the name "CAM4" is assigned automatically to source signal 4. Setting the source color of the video signal This sets the color displayed for 3rd row/4th row buttons and cross-point indicators on the cross-point control block or AUX bus control block. 1 Open the Engineering Setup >Panel >Xpt Assign >Src Name/Src Color menu (7322.6). 2 Select the target signal to set. 3 In the group, select the source color (User Color 1 to User Color 8). To change the colors of User Color 1 to 8 1 Press [User Color Select]. The User Color Select menu (7322.12) appears. 2 In the group, select the target color to set (User Color 1 to User Color 8). 3 In the group, select the color to set. To change the color, create a color by adjusting the following parameters. No. Parameter Adjustment 1 Red Red 2 Green Green 3 Blue Blue Note The color of the buttons may be different to the color adjusted using the menu. After adjusting the color, check the actual color of the button when it is lit. To return to the previous source color Press [Clear]. 4 Press [Execute]. Copying Cross-Point Assign Tables You can copy the contents of a cross-point assign table to another cross-point assign table. Note The contents of tables 1 to 14 cannot be copied to the main table. 1 In the Engineering Setup >Panel >Xpt Assign menu (7322), press [Table Copy]. The Table Copy menu (7322.8) appears. 2 Select the copy source and copy destination tables. 3 Press [Copy]. 4 Check the message, then press [Yes]. Selecting Cross-Point Assign Tables You can select the cross-point assign table to use for each of the banks or buses. Notes • It is not possible to assign cross-point assign tables 5 to 14 to a bus of a switcher operated by an MKS-8080/8082 AUX Bus Remote Panel. • On the cross-point control block, you can change the table using the cross-point assign table selection buttons on the cross-point pad. Different tables can be assigned to each cross-point button row. 1 In the Engineering Setup >Panel >Xpt Assign menu (7322), select the target bank or bus to set. 2 Select the table to assign. 3 Press [Table Assign Set]. Copying Cross-Point Settings To use the same cross-point settings as the switcher on a remote panel for the network AUX remote panel function, copy the cross-point assign table. You can assign the crosspoint settings of table 1 to the remote panel. For details about the network AUX remote panel function, see "Network AUX Remote Panel" (page 535). 415