Sony XVS-7000 Users Guide - Page 482
Configuring detailed settings for a TCP/IP, connected device, Zero based, SOM based
View all Sony XVS-7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 482 highlights
2 Select the port connected to the target AMP compatible device to set. 3 Press [Port Setting]. The AMP Setting menu (7355.8) appears. The slot number/port number, device type, port name, and control panel number appear at the top of the status area. The setting status of each item appears at the bottom of the status area. 4 In the group, select the type of timecode sense. Zero based: Mode in which timecode is sensed (detected), taking the first frame of the loaded file as 00:00:00:00. SOM based: Mode in which sensing occurs using the timecode saved in the loaded file. Note The details of the above operation modes depend on the connected device. For more information, refer to the documentation for the connected device. 5 Select the target item to set. 1. Maximum Open Delay: Maximum time required to open a file 2. Maximum Cueup Delay: Maximum time required to cue up a file 3. Play After Cueup Delay: Delay time from the cued-up state to begin playback 4. Stop Delay: Delay time from issuing the Stop command until actually stopping 5. Still Delay: Delay time from issuing the Still command until actually stopping 6. Command Delay (Auto Mode): Delay time from issuing the Auto Mode On/Off command until the command takes effect 7. Command Delay (Out Preset): Delay time from issuing the Out Preset command until the command takes effect 8. Command Delay (Preview In Preset): Delay time from issuing the Preview In Preset command until the command takes effect 9. IP Address: IP address setting 10. TCP/IP Port: TCP/IP port number setting 11. Video Port: Video port number (1 to 4) setting 12. Internal Parameter (1): Reserved for future use (set to 255) 13. Internal Parameter (2): Reserved for future use (set to 255) 14. Internal Parameter (3): Reserved for future use (set to 255) 6 Set the response speed or value. No. Parameter Adjustment 2 Setting Response speed or value When "IP Address" is selected Press [IP Address]. Enter the address using the keyboard window, press [Enter], then skip to step 8. When "TCP/IP Port" is selected Press [TCP/IP Port]. Enter the port number using the numeric keypad window, press [Enter], then skip to step 8. 7 Press [Set]. 8 Repeat steps 5 to 7 as required to make the settings for other items. Configuring detailed settings for a TCP/IP connected device 1 In the group of the Engineering Setup >DCU >Serial/Net Port Assign menu (7355), select the target to set (DCU1 or DCU2). 2 Select the port connected to the target device to set. 3 Press [Port Setting]. The General tcp/ip Setting menu (7355.9) appears. The slot number/port number, device type, port name, and control panel number appear at the top of the status area. The setting status of each item appears at the bottom of the status area. 4 Select the target item to set. 1. IP Address: IP address setting 2. Port: Port number setting 3. Internal Parameter (1): Reserved for future use (set to 255) 4. Internal Parameter (2): Reserved for future use (set to 255) 5. Internal Parameter (3): Reserved for future use (set to 255) 6. Internal Parameter (4): Reserved for future use (set to 255) 7. Internal Parameter (5): Reserved for future use (set to 255) 8. Internal Parameter (6): Reserved for future use (set to 255) 9. Internal Parameter (7): Reserved for future use (set to 255) 10. Internal Parameter (8): Reserved for future use (set to 255) 11. Internal Parameter (9): Reserved for future use (set to 255) 482