Sony XVS-7000 Users Guide - Page 485
Setting External Boxes 1 to 12, Setting the Group Number of a, Description Name/Alias Name
View all Sony XVS-7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 485 highlights
No. Parameter Adjustment 1 Source Source start address 2 Destination Destination start address 3 Level S-Bus/NS-Bus level Setting External Boxes 1 to 12 To obtain the signal selection status of external devices with a parallel input, assign a matrix as an external selector to S-Bus/NS-Bus space. 1 In the Engineering Setup >Router/Tally >Router menu (7361), press [External Box Assign]. The External Box Assign menu (7361.1) appears. 2 In the group, select the target to set (External Box 1 to 12). 3 In the group, select the number of inputs for the external box. No Assign: Do not use. 4×1: 4 inputs and 1 output 8×1: 8 inputs and 1 output 16×1: 16 inputs and 1 output 32×1: 32 inputs and 1 output Note The maximum total number of inputs for all 12 external boxes is 68. 4 Set the following parameters. No. Parameter Adjustment 1 Source Source start address 2 Destination Destination start address 3 Level S-Bus/NS-Bus level Coupling external boxes By coupling a number of external boxes, the number of inputs can be increased. This section describes the coupling of external boxes 1 and 2 as an example. 1 In the group of the Engineering Setup >Router/Tally >Router >External Box Assign menu (7361.1), select [External Box1]. 2 In the group, select [8×1]. 3 Set the following parameters. No. Parameter Adjustment 1 Source Source start address 2 Destination Destination start address 3 Level S-Bus/NS-Bus level 4 In the group, select [External Box2]. 5 In the group, select [32×1]. 6 Set the parameters. Set the [Destination] and [Level] parameters to the same values set in step 3. This automatically couples external boxes 1 and 2, which can be used an external box with 40 (8+32) inputs. Setting the Group Number of a Description Name/Alias Name Set the group number of an S-Bus description name or NS-Bus alias name. 1 In the group of the Engineering Setup >Router/Tally >Router menu (7361), press [Gp No]. 2 Set the following parameter. No. Parameter Adjustment 1 Gp No Group number of S-Bus description name/NS-Bus alias name a) a) Select 0 to 7 for S-Bus, or select 1 to 8 for NS-Bus. Note For S-Bus, the description name of group 0 is used if description names for groups 1 to 7 are not specified. Type+Num name is used if a description name for group 0 is not specified. 3 In the group, press [Set]. Note Send the configured S-Bus description name/NS-Bus alias name from the router/system controller. 485