Sony XVS-7000 Users Guide - Page 437
Settings Relating to Control Panel Management, Setting Beep Sound for Touch
View all Sony XVS-7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 437 highlights
Settings Relating to Control Panel Management Setting the Screen Saver This enables the menu display screen saver. 1 In the Engineering Setup >Panel >Maintenance menu (7327), press [Screen Saver], turning it on. 2 Set the following parameter. No. Parameter Adjustment 1 Sleep Time Time until screen saver starts operation (minutes) Setting the State of Buttons that are Not Lit In the Engineering Setup >Panel >Maintenance menu (7327), press [Panel Glow]. To make unlit buttons visible in dark lighting conditions (dimly lit state), press [Panel Glow], turning it on. To turn the display of unlit buttons off, press [Panel Glow], turning it off. Setting Beep Sound for Touch Operation In the Engineering Setup >Panel >Maintenance menu (7327), press [Touch Beep]. To enable the beep sound, press [Touch Beep], turning it on. To disable the beep sound, press [Touch Beep], turning it off. Setting Panel Sleep Mode This mode reduces the brightness of the buttons and display on the control panel. 1 In the Engineering Setup >Panel >Maintenance menu (7327), press [Panel Sleep Mode], turning it on. 2 Set the following parameter. No. Parameter Adjustment 1 Sleep Time Time until panel sleep mode starts operation (minutes) Adjusting the Brightness 1 In the Engineering Setup >Panel >Maintenance menu (7327), select the target to set. LCD Btn Brightness: Adjust the brightness of the LCD buttons in the cross-point pad, Flexi Pad control block, and utility/shotbox control block. Display Brightness: Adjust the brightness of the control panel organic EL (OLED) display. Switch Brightness: Adjust the brightness of the control panel buttons. 2 Set the following parameter. No. Parameter Adjustment 1 Brightness Brightness Calibrating the Touch Panel 1 In the Engineering Setup >Panel >Maintenance menu (7327), press [Touch Panel Calibration]. The following message appears. "To Perform calibration, please touch the center of each plus sign." 2 Press [Yes]. 3 Press the center of the plus sign displayed on the screen. The plus sign disappears and then reappears diagonally. 4 Press the center of the plus sign. Setting the Menu to Display at Startup 1 In the Engineering Setup >Panel >Maintenance menu (7327), press [Initial Menu Set]. 2 Enter the page number of the menu to set in the numeric keypad window. s Note To enable this setting, the initial state of the control panel when powered on must be set to one of the following. • Set to Resume mode 437