Sony XVS-7000 Users Guide - Page 477
GPI Output Settings, Configuring GPI Outputs
View all Sony XVS-7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 477 highlights
GPI Output Settings Configure the trigger type and other settings for each GPI output. GPI output via a network On GPI outputs via a network, GPI control is performed using serial tally protocol commands. GPI outputs can be configured in the same way as parallel output ports. Notes • To use GPI via a network, configuration of the SIU utility connector is required. For details, refer to the ICP-X7000 Installation Manual. • This uses a SIU serial tally port, hence the network port must be configured for a serial tally port. For details, see "Serial Tally Settings" (page 490). Configuring GPI Outputs 1 In the Engineering Setup >DCU >GPI Output Assign menu (7354), select the target GPI output to set. 2 In the group, select the trigger polarity. (Rising Edge): Trigger causes the relay to open or the output to go high level, and holds this state for the pulse width duration. (Falling Edge): Trigger causes the relay to close or the output to go low level, and holds this state for the pulse width duration. (Any Edge): When a trigger occurs, the relay opens/closes or the output goes high/low level, switching state. Status: The relay opens/closes or the output goes high/low level in response to the status. NOP (No Operation): The trigger has no effect on the relay state or the output level. 3 Set the pulse width and timing. No. Parameter Adjustment 3 Pulse Width 4 Timing Pulse width Output timing a) a) 1: Field 1, 2: Field 2, 3: Any Note When "Any Edge" is selected as the trigger type, only the [Timing] parameter is available. When "Status" is selected as the trigger type, there are no parameter settings. 4 In the group, select the control panel to handle the GPI output. PNL1: ID1 control panel PNL2: ID2 control panel PNL3: ID3 control panel When the action set in step 5 is executed on the control panel selected in this step, GPI output occurs. It is also possible to output error information. Note For GPI output via a network, SIU1 must be configured to use [PNL1], and SIU2 must be configured to use [PNL2]. [PNL3] cannot be used. 5 Select the action to set. No. Parameter Adjustment 2 Action Action selection 5 Reg No Register number 6 Press [Action Set]. Trigger type and actions list 1) • When the trigger type is other than "Status" M/E-x Keyx SS ? Recall, P/P Keyx SS ? Recall, No Action • When the trigger type is "Status" M/E-x Keyx SS ? Recall, P/P Keyx SS ? Recall, M/E-x Keyx On, P/P Keyx On, Error Make, Error Break, Keep Make, Keep Break, Device Recording, PREFS 1 to PREFS 16, No Action 1) M/E-x: where x is the M/E number (1 to 5) Keyx: where x is the key number (1 to 8) Testing trigger output In the Engineering Setup >DCU >GPI Output Assign menu (7354), press [Test Fire]. This outputs a trigger from the selected output port. Note This is no output when the trigger type is "Status." 477