M4300 Intelligent Edge Series Fully Managed Stackable Switches Term Description High Capacity Alarm Interval The interval in seconds over which the data is sampled and compared with the rising and falling thresholds. The range is 1 to 2147483647. The default is 1. High Capacity Alarm Sample Type The method of sampling the selected variable and calculating the value to be compared against the thresholds. Possible types are Absolute Value or Delta Value. The default is Absolute Value. High Capacity Alarm Absolute Value The absolute value (that is, the unsigned value) of the hcAlarmVariable statistic during the last sampling period. The value during the current sampling period is not made available until the period is complete. This object is a 64-bit unsigned value that is Read-Only. High Capacity Alarm Absolute Alarm Status This object indicates the validity and sign of the data for the high capacity alarm absolute value object (hcAlarmAbsValueobject). Possible status types are valueNotAvailable, valuePositive, or valueNegative. The default is valueNotAvailable. High Capacity Alarm Startup Alarm High capacity alarm startup alarm that may be sent. Possible values are rising, falling, or rising-falling. The default is rising-falling. High Capacity Alarm The lower 32 bits of the absolute value for threshold for the sampled statistic. The range is 0 Rising-Threshold Absolute to 4294967295. The default is 1. Value Low High Capacity Alarm The upper 32 bits of the absolute value for threshold for the sampled statistic. The range is 0 Rising-Threshold Absolute to 4294967295. The default is 0. Value High High Capacity Alarm Rising-Threshold Value Status This object indicates the sign of the data for the rising threshold, as defined by the objects hcAlarmRisingThresAbsValueLow and hcAlarmRisingThresAbsValueHigh. Possible values are valueNotAvailable, valuePositive, or valueNegative. The default is valuePositive. High Capacity Alarm Falling-Threshold Absolute Value Low The lower 32 bits of the absolute value for threshold for the sampled statistic. The range is 0 to 4294967295. The default is 1. High Capacity Alarm Falling-Threshold Absolute Value High The upper 32 bits of the absolute value for threshold for the sampled statistic. The range is 0 to 4294967295. The default is 0. High Capacity Alarm Falling-Threshold Value Status This object indicates the sign of the data for the falling threshold, as defined by the objects hcAlarmFallingThresAbsValueLow and hcAlarmFallingThresAbsValueHigh. Possible values are valueNotAvailable, valuePositive, or valueNegative. The default is valuePositive. High Capacity Alarm Rising Event Index The index of the eventEntry that is used when a rising threshold is crossed. The range is 1 to 65535. The default is 1. High Capacity Alarm Falling Event Index The index of the eventEntry that is used when a falling threshold is crossed. The range is 1 to 65535. The default is 2. High Capacity Alarm Failed Attempts The number of times the associated hcAlarmVariable instance was polled on behalf of thie hcAlarmEntry (while in the active state) and the value was not available. This object is a 32-bit counter value that is read-only. High Capacity Alarm Owner The owner string associated with the alarm entry. The default is monitorHCAlarm. High Capacity Alarm Storage Type The type of non-volatile storage configured for this entry. This object is read-only. The default is volatile. Utility Commands 357 CLI Command Reference Manual