www.dell.com | support.dell.com Defaults Command Modes Command History Usage Information No MD5 authentication is configured. INTERFACE Version 8.3.19.0 Version 8.3.7.0 Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.1 Introduced on S4820T Introduced on S4810 Introduced on S-Series Introduced on C-Series Introduced on E-Series To change to a different key on the interface, enable the new key while the old key is still enabled. The FTOS will send two packets: the first packet authenticated with the old key, and the second packet authenticated with the new key. This process ensures that the neighbors learn the new key and communication is not disrupted by keeping the old key enabled. After the reply is received and the new key is authenticated, you must delete the old key. Dell Force10 recommends keeping only one key per interface. Note: The MD5 secret is stored as plain text in the configuration file with service password encryption. ip ospf mtu-ignore c e s Disable OSPF MTU mismatch detection upon receipt of database description (DBD) packets. Syntax ip ospf mtu-ignore To return to the default, enter no ip ospf mtu-ignore. Defaults Enabled Command Modes INTERFACE Command History Version 8.3.19.0 Version 8.3.7.0 Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.1 Introduced on S4820T Introduced on S4810 Introduced on S-Series Introduced on C-Series Introduced on E-Series ip ospf network c e s Set the network type for the interface. 1098 | Open Shortest Path First (OSPFv2)