Dell Force10 S4820T FTOS Command Reference Guide - Page 1292
rmon alarm, c e s z
View all Dell Force10 S4820T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1292 highlights
www.dell.com | support.dell.com rmon alarm c e s z • rmon collection statistics • rmon event • rmon hc-alarm • show rmon • show rmon alarms • show rmon events • show rmon hc-alarm • show rmon history • show rmon log • show rmon statistics Set an alarm on any MIB object. Syntax Parameters rmon alarm number variable interval {delta | absolute} rising-threshold value event-number falling-threshold value event-number [owner string] To disable the alarm, use the no rmon alarm number command. number variable interval delta absolute rising-threshold value event-number Enter the alarm integer number from 1 to 65535. The value must be unique in the RMON Alarm Table. The MIB object to monitor. The variable must be in the SNMP OID format, for example, 1.3.6.1.2.1.1.3 The object type must be a 32 bit integer. Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON Alarm table. Range: 5 to 3600 seconds Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON Alarm table. Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON Alarm table. Enter the keyword rising-threshold followed by the value (32bit) the rising-threshold alarm is either triggered or reset. Then enter the event-number to trigger when the rising threshold exceeds its limit. This value is the same as the alarmRisingEventIndex or alarmTable of the RMON MIB. If there is no corresponding rising-threshold event, the value is zero. 1292 | Remote Monitoring (RMON)